APP-FND-204 Concurrent Manager encountered an error while running the spawned concurrent program Receiving Transaction Manager - RCVOLTM for your concurrent request XXXXXX. TM-SVC LOCK HANDLE FAILED

This is happening because of large number of receiving processes being spawned at the same time.

Navigation:
  • System Administrator (or comparable) Responsibility > Concurrent > Manager > Define
  • Query for Manager='Receiving Transaction Manager'
  • Click Work Shifts button and review value in Processes field (Increase the number of process)
  • Go to: Concurrent -> Manager -> Administer
  • Restart and Activate the Receiving Transaction Manager
  • Refresh to check to make sure the target and actual processes = desired number of processes
  • Retest the issue

If steps above still does not work, please perform the ADRELINK utility on the executable
as follows:

At UNIX prompt:
cd $PO_TOP/bin
adrelink.sh force=y ranlib=y "po RCVOLTM"

This relinks the executable for the Receiving Transaction Manager which is RCVOLTM. Now shut down and restart the Receiving Transaction Manager, you may have to click on RESTART, then
REFRESH and then click on ACTIVATE.